Lomax System Stock Calculator

Select the best layout, enter your dimensions and get an instant estimate of the Lomax System modular components required for your project
(just add your own panels and timbers)

1 Choose your closest layout

2 Confirm the environment & dimensions

Choose indoor or outdoor first

Choose the indoor standard

Outdoors, TWf compliance is at the 0.36 kN/m pedestrian load only. The heavier TWf loads (0.74 kN/m and 1.5 kN/m crowd loading) are indoor only: they are not certified outdoors and are not offered here.

Quantities from the Lomax System – Smartbuild Engineering wind calculator (UK_2.07), certified by Smartbuild Engineering Ltd (certificate 1307-CS02) to TWf2012:01 (revised August 2020), with Factor of Safety 1.5 and a 0.36 kN/m pedestrian load check (BS1722-14).

Enter the first half of the postcode (for example SW1A or M1), or the full postcode if you have it. For Northern Ireland, please enter the full postcode. We'll find the basic wind speed, altitude and whether you are near the coast.

Great Britain outcode locations and Northern Ireland postcode-sector locations are from the ONS Postcode Directory (November 2025) and postcodes.io, used under the Open Government Licence v.3.0. Contains OS data © Crown copyright and database right 2026. Contains Royal Mail data © Royal Mail copyright and database right 2026. A full postcode is refined from postcodes.io when a network connection is available. Altitude is a suggestion from Mapzen terrain tiles (CC BY 4.0). Distance to shoreline is a suggestion measured to a Natural Earth coastline. Please confirm both.

Select the site design wind speed from your structural engineer (shown in m/s and mph).

Site-specific design wind speed must be determined by a competent person (structural engineer). Using your own wind speed is your engineer's responsibility. Lomax System cannot set the wind speed for your site.

3 Estimated Lomax System Components Required

This calculator covers Lomax System components only. The client is to supply their own panels, timbers, doors, screws etc. Panel options include marine ply, melamine, MDF, particle board or sandwich panel (all min. 12 mm).

Your email app will open with your stock list. Please add your name, company, phone and site location before you send, so we can prepare your formal quote.

Important: This is an estimating tool only. Final quantities must be confirmed against the Lomax System Technical & Installation Guide and any site-specific structural engineering requirements, especially for outdoor wind or if an indoor environment were to change.

"*" indicates required fields

This field is for validation purposes and should be left unchanged.
Accepted file types: pdf, Max. file size: 10 MB.

Calculate the type and quantity of Lomax System components you need for your project

Our reusable, modular components can deliver a range of structurally engineered and compliant configurations for:

  • Indoor hoardings (up to 6mH)
  • Outdoor hoardings (up to 4mH with various wind speeds)

We have completed the required testing for all configurations and provide simple guides so that the correct volume of counterweight is used in accordance to its environment for compliance.

It’s really simple and all structural engineering documents are provided.

Indoor Hoarding Example (for Impact and Climb Test Capability)

Our counterweights are 18Kg each so for an indoor hoarding at 2.4mH it only requires 3 x Lomax Counterweights (per stack) and 1 x Large Lomax Support Post on the rear of each panel join at max 1.2mW spacing to support the panels and timbers.

Then for 3.6mH it only requires 4 x Lomax Counterweights (per stack) and 1 x Large Lomax Support

Our easy calculator confirms the quantity of Lomax counterweights that you’d need for indoor hoardings to freestand up to a massive 6mH.

Outdoor Hoardings

Outdoor hoardings need to mitigate and manage the additional wind pressure of the specific location / environment they are in.

Factors such as Topography, Shielding and Terrain need to be considered for the specific location of your installation..

Unlike an indoor hoarding, you may also need to construct an outdoor hoarding with a ‘double stack’ of counterweights or even space them closer at 0.6mW intervals so you can achieve greater mass weight for overall stability and compliance – We have specifically designed a ‘Double-Stack Support Post’ to offer the easiest approach to constructing an outdoor hoarding that requires this ‘double stack’ of counterweights.

We have developed a simple ‘System Configurator’ that can assist you with your build requirements and confirm the quantity of weight required for multiple wind speeds.

Outdoor Hoarding Example

An outdoor hoarding at 2.4mH with a wind speed capability of 51Mph might require a double stack of ‘8+8’ x Lomax Counterweights (back-to-back) and 1 x Double Support Post on the rear of each panel join at 1.2mW spacing / intervals to support the panels and timbers that you would add.

We have completed the wind computations for many outdoor configurations and provide a simply guide so that you can offer the correct ‘weight-to-height-to-wind speed’ ratio – It’s very easy and all instructions are provided.

Use our simple ‘Lomax System – Outdoor Configurator’ to understand what quantity of modular components you would need for your project.

Lomax Technical and Installation Guide

The intent of this guide is to clearly describe and illustrate the build process and structural certification parameters of the various indoor and outdoor modular configurations for the Lomax Hoarding System – For additional information please contact us.

National Hoarding Design & Installation Service

If you would prefer us (or one of our many certified installation partners) to manage your hoarding installation and would rather not the hire or purchase of the structural equipment yourselves, we provide a complete hoarding design and installation service for you nationwide. Find out more about national hoarding design and installation.

Lomax System Technical and Installation Guide

The intent of this ‘Technical and Installation Guide’ is to clearly describe and illustrate the build process and structural certification parameters of the various configurations for the ‘Lomax System’ in accordance to the testing of the system that was completed by the independent structural engineers.

Make an Enquiry

Buy or hire the ‘Lomax System Components’ so you can add your own panels/timbers and self-install your solution OR have the Lomax System teams or certified installation partners supply everything and install/remove it for you.

Lomax System Support Hub

Certification Documents | Marketing Material | Training Platform